Key result
A prototype cell-based electrochemical biosensor rapidly detected infectious Hepatitis A virus with a limit of detection of ~5 TCID50/mL and a significant linear relationship (R2 = 0.98).
Why the study?
Current standardized methods for hepatitis A virus rely on detecting viral antigen or RNA and do not differentiate between infectious and non-infectious virus.
A prototype cell-based electrochemical biosensor can rapidly and specifically detect low levels of infectious Hepatitis A virus.
Answers are grounded in this paper and cite their sources.
Prototype biosensor may distinguish infectious HAV; leaves open clinical validation before diagnostic use.
Hepatitis A virus (HAV), a major cause of acute liver infections, is transmitted through the fecal–oral route and close contact with infected individuals. Current HAV standardized methods rely on the detection of virus antigen or RNA, which do not differentiate between infectious and non-infectious HAV. The objective of this study was to develop a prototype cell-based electrochemical biosensor for detection of infectious HAV. A cell culture-adapted HAV strain (HM175/18f) and its permissive cells (FRhK-4), along with gold nanoparticle-modified screen-printed electrodes, were used to develop the biosensor. Electrochemical impedance spectroscopy was used to quantify the electrical impedance signal. Nyquist plots showed successful fabrication of the cell-based biosensor. The optimum period of HAV incubation with the biosensor was 6 h. A significant linear relationship (R2 = 0.98) was found between the signal and a 6-log range of HAV titers, with a limit of detection of ~5 TCID50/mL (tissue culture infectious dose). The biosensor did not detect non-target viruses such as feline calicivirus and human coronavirus 229E. The biosensor was stable for 3 to 7 days at an abusive temperature (37 °C), retaining ~90 to 60% of the original signal, respectively. In conclusion, this prototype cell-based biosensor is capable of rapidly detecting low levels of infectious HAV.
No takes yet. Share an insight, caveat, or question.
Kaur et al. (2024) studied Hepatitis A virus (HAV). Cell-based electrochemical biosensor vs. Non-target viruses (feline calicivirus, human coronavirus 229E) was evaluated on Detection of infectious HAV titers (R2 = 0.98). A prototype cell-based electrochemical biosensor rapidly detected infectious Hepatitis A virus with a limit of detection of ~5 TCID50/mL and a significant linear relationship (R2 = 0.98).
Synapse has enriched 10 related papers. Consider them for comparative context: