Key result
At medium-term follow-up after SAVR with the Intuity Elite prosthesis, 44% of new left bundle branch blocks and 50% of new right bundle branch blocks had disappeared.
Why the study?
Postoperative conduction disorders, especially LBBB, are increased after rapid deployment Intuity Elite aortic valve replacement, but their behavior at intermediate follow-up was unclear.
Does the incidence of conduction disorders after surgical aortic valve replacement using a rapid deployment prosthesis decrease at medium-term follow-up?
Cohort (n=87)
Does the incidence of conduction disorders after surgical aortic valve replacement using a rapid deployment prosthesis decrease at medium-term follow-up?
Conduction disorders, particularly LBBB, frequently occur after rapid deployment SAVR but resolve in nearly half of patients at medium-term follow-up.
New conduction disorders after rapid deployment SAVR often resolve without AV block progression; leaves open need for randomized validation.
BACKGROUND: We have previously reported that the incidence of postoperative conduction disorders, especially left bundle branch block (LBBB), after implantation of a rapid deployment Intuity™ Elite aortic valve prosthesis (Edwards Lifesciences, Irvine, CA, USA), was significantly increased compared with conventional aortic valve replacement. We were now interested in how these disorders behaved at intermediate follow-up. METHODS: All 87 patients who had undergone surgical aortic valve replacement (SAVR) using the rapid deployment Intuity™ Elite prosthesis and were shown to have conduction disorders at the time of hospital discharge were followed up after surgery. These patients' ECGs were recorded at least 1 year after surgery, and the persistence of the new postoperative conduction disorders was assessed. RESULTS: At hospital discharge, 48.1% of the patients had developed new postoperative conduction disorders, with LBBB being the predominant conduction disturbance (36.5%). At medium-term follow-up (526 days, standard deviation (SD) = 169.6, standard error (SE) = 19.3 days, respectively), 44% of the new LBBB and 50% of the new right bundle branch block (RBBB) had disappeared. There was no new atrio-ventricular block III (AVB III) that occurred. One new pacemaker (PM) was implanted during follow-up because of AVB II Mobitz type II. CONCLUSIONS: At medium-term follow-up after the implantation of a rapid deployment Intuity™ Elite aortic valve prosthesis, the number of new postoperative conduction disorders, especially LBBB, has considerably decreased but remains high. The incidence of postoperative AV block III remained stable.
No takes yet. Share an insight, caveat, or question.
Mogilansky et al. (2023) conducted a cohort in Conduction disorders after surgical aortic valve replacement (n=87). Surgical aortic valve replacement using the rapid deployment Intuity™ Elite prosthesis was evaluated on Disappearance of new postoperative left bundle branch block (LBBB). At medium-term follow-up after SAVR with the Intuity Elite prosthesis, 44% of new left bundle branch blocks and 50% of new right bundle branch blocks had disappeared.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: