Answers are grounded in this paper and cite their sources.
A microcarbon array electrode was modified by the placement of a Nafion film containing cobalt tetra‐methylpyridyl phorphyrin on its surface. This electrode was applied to the analysis of solution glucose when it was further modified by the immobilization of glucose oxidase on the outermost surface of the Nafion by the cross‐linking of serum albumin with glutaraldehyde. The concomitant decrease in the concentration of oxygen, as it was consumed in the enzymatic reaction of glucose with glucose oxidase, was determined by either cyclic voltammetry or a double potential step method at the porphyrin‐Nafion catalytic electrode. Glucose could be determined in the range, of 0.01‐;4 mM rapidly, without interference from substances such as accurate or other saccharides.
No takes yet. Share an insight, caveat, or question.
Dong et al. (1991) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: