OBJECTIVE: We evaluated the results of thoracic endovascular aneurysm repair (TEVAR) to determine what anatomic factors influenced the clinical outcomes. METHODS: Preoperative computed tomography (CT) angiograms of 65 patients who underwent TEVAR were analyzed using 3-dimensional imaging. The proximal and distal neck, thoracic aneurysm, and iliac arteries were measured for angulation, diameter, length, calcification, and tortuosity. Immediate technical success and clinical success were measured. RESULTS: Immediate technical success was achieved in 91% (59 of 65) of the patients analyzed. One patient died in the operating room during treatment of rupture. Clinical success was achieved in 83% (54 of 65) of patients at follow-up. Four patients had small endoleaks with no sac enlargement at follow-up. One patient was converted to open repair. Severe iliac calcification was found to be significant for deployment failure. The mean follow-up is 8 months (1-36 months). CONCLUSION: Increased iliac calcification and increased iliac tortuosity correlate with an inability to successfully deploy the device.
No takes yet. Share an insight, caveat, or question.
Bowman et al. (2009) studied this question.
Synapse has enriched 3 closely related papers on similar clinical questions. Consider them for comparative context: