Answers are grounded in this paper and cite their sources.
In Brief Background: Because plantar anatomic features are similar to those of the palmar surface of the finger, palmar surface finger reconstruction using a medial plantar venous flap enables grasping without slippage, results in strength that can withstand friction, and provides a cushioning effect. Furthermore, sensory restoration is thought to be excellent due to the similarity of the tissues. Methods: We performed finger palmar surface reconstruction in 6 patients using venous flap without harvesting the medial plantar subcutaneous nerve branch and assessed the sensory restoration using a static 2-point discrimination test (s-2PD), moving 2-point discrimination test (m-2PD), and Semmes-Weinstein test (S-W test). Results: The mean s-2PD at 12 months after surgery was 8.6 mm, the mean m-2PD was 6.00 mm, and the S-W test score was 3.84–3.22 Conclusion: These findings indicate that sensory improvement can be obtained by finger palmar surface reconstruction without grafting of the medial plantar subcutaneous nerve branch to the digital nerve. Six volar finger-resurfacing procedures were successfully achieved using flow-through venous flaps from the medial plantar area. Despite not incorporating a nerve in the flap, 6.0 mm mean m-2PD was achieved.
No takes yet. Share an insight, caveat, or question.
Yokoyama et al. (2006) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: