Key result
Iatrogenic upper limb ischemia during aortic surgery significantly lowered right-arm venous oxygen saturation and NIRS values and increased lactate levels compared to the left arm.
Why the study?
Does upper limb ischemia-reperfusion during aortic surgery with moderate hypothermia alter regional oxidative stress biomarkers, lactate, and NIRS values compared to non-ischemic regions?
Observational
Does upper limb ischemia-reperfusion during aortic surgery with moderate hypothermia alter regional oxidative stress biomarkers, lactate, and NIRS values compared to non-ischemic regions?
Traditional markers like lactate and NIRS reflect regional ischemia-reperfusion more rapidly and reliably than novel oxidative stress biomarkers during aortic surgery with axillary cannulation.
Venous biomarker and NIRS sampling during aortic surgery warrants validation; leaves open utility for guiding antegrade cerebral perfusion.
INTRODUCTION: pressure, near-infrared spectroscopy (NIRS) measurements, and biomarkers like sialic acid, malondialdehyde, advanced oxidative protein products in aortic surgery with moderate hypothermia. METHODS: Adult patients undergoing ascending aorta repair with antegrade cerebral perfusion via the axillary artery participated. Blood samples were collected from the internal jugular vein, right arm cubital vein, and left arm cubital vein, and analysis was performed at intraoperative time points. RESULTS: Right-arm venous oxygen saturation levels are significantly lower than left arm and central venous, as expected in iatrogenic ischemia. Right arm lactate levels are significantly higher. Somatic right arm NIRS values are significantly lower than somatic left arm. There are no significant differences for biomarkers throughout the time points. CONCLUSIONS: We have concluded that well-known markers reflect the results of ischemia-reperfusion more rapidly, and are more valuable than novel biomarkers. NIRS is a promising monitor in terms of providing information about tissue oxygenation. Oxidative stress biomarkers do not change quickly enough to give useful information in a short enough period of time; moreover, their costs are high and laboratory studies take time. Although axillary cannulation is controlled limb ischemia, the local effects of I/R did not completely normalize at the end of the surgery, and this regional I/R did not affect the global body organism.
No takes yet. Share an insight, caveat, or question.
Balcı et al. (2021) conducted an observational in Ascending aorta repair. Axillary cannulation (iatrogenic upper limb ischemia) vs. Left arm and central venous measurements was evaluated on Venous oxygen saturation, lactate levels, NIRS values, and oxidative stress biomarkers. Iatrogenic upper limb ischemia during aortic surgery significantly lowered right-arm venous oxygen saturation and NIRS values and increased lactate levels compared to the left arm.