Key result
Measuring aortic regurgitation in 4D flow CMR at the level of the pulmonary arteries yielded the best agreement with 2D phase contrast measurements (ICC 0.994) and the highest reproducibility.
Why the study?
The optimal anatomical level to measure aortic flow for quantification of aortic regurgitation in 4D flow CMR was unknown.
At which anatomical level does 4D flow CMR provide the most reproducible and accurate quantification of aortic regurgitation compared to 2D phase contrast CMR?
Cross-Sectional (n=27)
Blinded observers
No
At which anatomical level does 4D flow CMR provide the most reproducible and accurate quantification of aortic regurgitation compared to 2D phase contrast CMR?
For quantifying aortic regurgitation using 4D flow CMR, measurements at the level of the pulmonary arteries provide the best reproducibility and agreement with 2D phase contrast imaging.
PURPOSE: To find the best level to measure aortic flow for quantification of aortic regurgitation (AR) in 4D flow CMR. METHODS: In 27 congenital heart disease patients with AR (67% male, 31 ± 16 years) two blinded observers measured antegrade, retrograde, net aortic flow volumes and regurgitant fractions at 6 levels in 4D flow: (1) below the aortic valve (AV), (2) at the AV, (3) at the aortic sinus, (4) at the sinotubular junction, (5) at the level of the pulmonary arteries (PA) and (6) below the brachiocephalic trunk. 2D phase contrast (2DPC) sequences were acquired at the level of PA. All patients received prior transthoracic echocardiography (TTE) with AR severity grading according to a recommended multiparametric approach. RESULTS: After assigning 2DPC measurements into AR grading, agreement between TTE AR grading and 2DPC was good (κ = 0.88). In 4D flow, antegrade flow was similar between the six levels (p = 0.87). Net flow was higher at level 1-2 than at levels 3-6 (p < 0.05). Retrograde flow and regurgitant fraction at level 1-2 were lower compared to levels 3-6 (p < 0.05). Reproducibility (inter-reader agreement: ICC 0.993, 95% CI 0.986-0.99; intra-reader agreement: ICC 0.982, 95%CI 0.943-0.994) as well as measurement agreement between 4D flow and 2DPC (ICC 0.994; 95%CI 0.989 - 0.998) was best at the level of PA. CONCLUSION: For estimating severity of AR in 4D flow, best reproducibility along with best agreement with 2DPC measurements can be expected at the level of PA. Measurements at AV or below AV might underestimate AR.
No takes yet. Share an insight, caveat, or question.
Polacin et al. (2022) conducted a cross-sectional in Congenital heart disease with aortic regurgitation (n=27). 4D flow CMR measurement at the level of the pulmonary arteries vs. 2D phase contrast CMR was evaluated on Measurement agreement between 4D flow and 2D phase contrast for regurgitant fraction (ICC 0.994, 95% CI 0.989-0.998). Measuring aortic regurgitation in 4D flow CMR at the level of the pulmonary arteries yielded the best agreement with 2D phase contrast measurements (ICC 0.994) and the highest reproducibility.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: