This study aims to investigate the effect of blast loads generated as a result of explosive charges on the existing exterior RC circular columns of a typical building in the city of Riyadh. A procedure has been developed for evaluating the dynamic characteristics of the circular column with and without retrofitting. A wide range of parametric studies have been performed as part of this investigation to examine the effects of stand-off distance, charge weight and the presence of CFRP retrofitting on the level of damage to the RC column. The nonlinear finite element analysis was carried out using LS-DYNA software with explicit time integration algorithms. Different charge weights of 100, 200, 500 and 1000 kg equivalent weight of TNT at stand-off distances of 1, 4 and 15 m were considered. Results described in this paper indicate that CFRP strengthening could be an effective solution to limit the damage caused by moderate explosions. The stand-off distance was found to play a very important role in mitigating the adverse effects of a blast. The results also indicate that the maximum lateral deflection experienced by the column decreased exponentially with the increase in the stand-off distance and also decreased for the columns strengthened with CFRP, compared with the unstrengthened columns.
No takes yet. Share an insight, caveat, or question.
Elsanadedy et al. (2011) studied this question.
Synapse has enriched 5 related papers. Consider them for comparative context: