Key result
Analytical modeling demonstrated that blood velocity for a dilatant fluid is higher than for viscous and pseudoplastic fluids in the core region of a diseased tapered inclined artery, and wall shear stress is higher in stenosed arteries compared to healthy ones.
Why the study?
To demonstrate the implications of heat transfer and chemical reactions on the flow of a Carreau-Yasuda fluid through a diseased tapered inclined artery with mild stenosis.
Does not alter stenosis management; leaves open experimental validation of non-Newtonian flow models in diseased arteries.
This paper demonstrates the implications of heat transfer and chemical reactions by considering the flow of a Carreau-Yasuda fluid through the diseased tapered inclined artery. The analysis has performed on the artery with mild stenosis. The analytical solution has been obtained using the perturbation method due to its low Weissenberg number to get the blood velocity, the wall shear stress distribution, the temperature, the concentration, the resistance impedance and the stream function. The critical results in this study have depicted that the blood velocity for dilatant fluid is higher than that in viscous and pseudoplastic fluids in the core region of the artery. The value of blood velocity through a Newtonian fluid is extraordinarily lower than that through a Carreau-Yasuda fluid at the core region of the artery. The magnitude of blood velocity across the vertical artery is higher than those in the inclined and horizontal arteries inside the core region of the artery. The wall shear stress distributions are higher in the case of stenosis (diseased artery) than in no stenosis (healthy artery). The temperature transmission for the Carreau fluid is higher than that for the Carreau-Yasuda fluid. The flow resistance progressively increases as the depth of the stenosis increases. The size of the trapping bolus gradually increases, shifting toward the right at the diverging tapering artery, and it gradually increases, moving toward the left at the converging tapering artery. Finally, the streamlines are noticeably more comprehensive along the vertical artery and are higher than those in the inclined and horizontal arteries.
No takes yet. Share an insight, caveat, or question.
M. A. El Kot (2022) studied Arterial stenosis (mathematical model). Carreau-Yasuda fluid model with heat transfer and chemical reactions vs. Newtonian fluid model / healthy artery was evaluated on Blood velocity, wall shear stress, temperature, concentration, and resistance impedance. Analytical modeling demonstrated that blood velocity for a dilatant fluid is higher than for viscous and pseudoplastic fluids in the core region of a diseased tapered inclined artery, and wall shear stress is higher in stenosed arteries compared to healthy ones.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: