The purpose of this study was to determine the predictor variables for breathlessness and to investigate the criteria of reliability and responsiveness for measuring breathlessness during progressive, incremental exercise on the cycle ergometer. We studied a heterogeneous group of patients with stable asthma (mean ± SEM age, 46 ± 4 yr) for four visits at weekly intervals. Predictor variables were determined at the first visit. Nine independent physiologic variables were obtained at each minute during exercise; the Borg rating of breathlessness (range 0 to 10) was used as the dependent variable. The regression model relating the physiologic parameters to the Borg rating of breathlessness was highly significant (model F = 43.4; p = 0.0001). Backward elimination selected the strongest predictors of the Borg rating: peak inspiratory flow ( i); tidal volume (Vt)/FVC; frequency of respiration (f); and peak inspiratory mouth pressures (Pm). These four variables explained 63% of the variance in the rating of dyspnea. Each of the four variables exhibited a linear relationship with the Borg rating. Test-retest reliability was assessed by comparing results at the first and second visits. Individual slopes (except for Vt/FVC) and intercepts for the four predictor variables versus Borg ratings were highly reliable. The slope for work intensity (watts) and Borg ratings, but not the intercept, was highly reliable. Responsiveness was evaluated by randomly administering inhaled methacholine or inhaled metaproterenol, alternately, at the third and fourth visits to induce acute changes in lung function before exercise. Despite substantial bronchoconstriction (−36 ± 3% in FEV1) and bronchodilation (14 ± 3% in FEV1), analysis of variance showed no significant differences for slopes or intercepts for i-Borg, Vt/FVC-Borg, f-Borg, or Pm-Borg. In contrast, the intercept (but not the slope) for work intensity-Borg ratings was significantly higher after bronchoconstriction compared with Visit 2 or after bronchodilation (p = 0.0001). We conclude that (1) exercise i, Vt/FVC, f, and Pm were significant predictor variables for Borg ratings of breathlessness; (2) relationships between physiologic variables versus Borg ratings as well as work versus Borg ratings were generally highly reliable; and (3) only the relationship (intercept) between work intensity and Borg ratings was sensitive to acute bronchoconstriction.
No takes yet. Share an insight, caveat, or question.
Mahler et al. (1991) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: