Answers are grounded in this paper and cite their sources.
This study deals with gaseous insulation contaminated by free moving particles. Two gases were investigated: SF6 (0.45 MPa) and a CO2/O2 gas mixture (0.75 MPa). Video recordings were used to track a free particle moving between a plate and a Rogowski electrode for validation of a 1D particle motion model. The effect of fixed and free particles (4 or 8 mm, Ø 0.9 mm) on the breakdown voltage and the mean time between breakdowns was determined in a concentric set of electrodes. The value of the breakdown voltage for a free particle was between those of a particle fixed to the enclosure and the central electrode. The particle motion in the concentric case could not be observed in the experimental set-up and was therefore simulated using a 1D model. For the 4 mm free particle, the breakdown seemed to be initiated in the inter-electrode gap in CO2 and at the crossing in SF6, while for the 8 mm particle, breakdown occurred at lift-off in both gases. A parameter k describing the width of the time to breakdown distribution was introduced. A low value of k was associated with the breakdown from the particles at the electrodes, while k was larger than 10 when the breakdown was decided during particle flight.
No takes yet. Share an insight, caveat, or question.
Donzel et al. (2022) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: