Adaptive optics systems provide a real-time compensation for atmospheric turbulence. However, the correction is often only partial, and a deconvolution is required for reaching the diffraction limit. The need for a regularized deconvolution is discussed, and such a deconvolution technique is presented. This technique incorporates a positivity constraint and some a priori knowledge of the object (an estimate of its local mean and a model for its power spectral density). This method is then extended to the case of an unknown point-spread function, still taking advantage of similar a priori information on the point-spread function. Deconvolution results are presented for both simulated and experimental data.
No takes yet. Share an insight, caveat, or question.
Conan et al. (1998) studied this question.
Synapse has enriched 4 closely related papers on similar clinical questions. Consider them for comparative context: