Key result
False lumen occlusion using the Candy-Plug generation II in chronic aortic dissection achieved 100% technical success and 93% clinical success.
Why the study?
To present early results of false lumen occlusion in chronic aortic dissection using the Candy-Plug generation II, which features a self-closing fabric channel.
Does thoracic endovascular aortic repair with the Candy-Plug generation II achieve technical and clinical success in patients with chronic aortic dissection and persistent false lumen backflow?
Observational (n=14)
Does thoracic endovascular aortic repair with the Candy-Plug generation II achieve technical and clinical success in patients with chronic aortic dissection and persistent false lumen backflow?
The Candy-Plug generation II device is highly feasible for false lumen occlusion in chronic aortic dissection, achieving 100% technical success and promoting early aortic remodeling.
Supports feasibility of Candy-Plug II in select chronic dissections; leaves open durability and broader applicability pending prospective data.
Purpose: To present the early results of false lumen (FL) occlusion in chronic aortic dissection using the Candy-Plug generation II (CP II), which has a self-closing fabric channel that obviates the need for separate occlusion of its center. Materials and Methods: Fourteen consecutive patients (mean age 60±11 years; 10 men) with persistent FL backflow and aneurysm formation at the thoracic segment in chronic aortic dissection underwent thoracic endovascular aortic repair (TEVAR) with FL occlusion using the refined CP II. Primary endpoints were technical success (successful deployment) and clinical success (no FL backflow at the CP II level). Secondary endpoints included 30-day mortality and morbidity and aortic remodeling during follow-up. Results: Technical success was 100%. One patient required additional intraprocedural FL embolization at the CP II level due to persistent FL backflow on final angiography (clinical success 93%), though there was no flow through the CP II center. There were no intraprocedural complications. Immediate complete FL occlusion was achieved in 12 patients; the other 2 required reintervention. One had contrast enhancement in the distal FL proximal to the CP II and was treated with coil embolization. The other patient had persistent type I endoleak at the level of the left subclavian artery (LSA) and underwent left carotid–LSA bypass and proximal stent-graft extension. One patient died due to retrograde type A aortic dissection that was not related to CP II placement. Over a mean 8-month follow-up (range 3–12), 9 patients had computed tomography angiography; 8 patients had evidence of aortic remodeling, while 1 aneurysm sac was stable. Conclusion: The CP II reduces the number of procedural steps and offers good seal, with minimal morbidity and mortality and a high rate of aortic remodeling.
No takes yet. Share an insight, caveat, or question.
Eleshra et al. (2019) conducted an observational in Chronic aortic dissection (n=14). Candy-Plug generation II (CP II) for false lumen occlusion was evaluated on Technical success (successful deployment) and clinical success (no FL backflow at the CP II level). False lumen occlusion using the Candy-Plug generation II in chronic aortic dissection achieved 100% technical success and 93% clinical success.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: