January 1, 1998IEEE Transactions on Biomedical Engineering136 citations

Fetal ECG extraction with nonlinear state-space projections

View Full Paper
MRMark RichterTSThomas SchreiberDKDaniel T. Kaplan

Key Result

A nonlinear state-space projection technique successfully suppresses maternal and noise contaminations in single-lead fetal ECG recordings with comparable fetal and noise amplitudes.

Structured PICO

P
Population
Single-lead fetal ECG recordings
I
Intervention
Nonlinear state space projection technique
O
Outcome
Suppression of maternal and noise contaminationssurrogate

Nonlinear state-space projections can effectively extract fetal ECG signals from noisy single-lead recordings.

Abstract

We describe a method to suppress maternal and noise contaminations in single-lead fetal ECG recordings. A nonlinear state space projection technique originally developed for noise reduction in deterministically chaotic signals is used. The method is successfully applied to recordings with fetal components and noise of comparable amplitude.

Ask AI
Helpful
Bookmark
Share
View Full Paper

Cite This Study

Richter et al. (1998) studied this question. A nonlinear state-space projection technique successfully suppresses maternal and noise contaminations in single-lead fetal ECG recordings with comparable fetal and noise amplitudes.

synapsesocial.com/papers/6a9a376fa0ce302fc2a0b9dchttps://doi.org/10.1109/10.650369