Two laboratory assistants developed contact dermatitis from a disposable swab for pre-injection use, containing isopropyl alcohol 70% and propylene oxide 1%. Patch testing gave position allergic reactions to propylene oxide in both patients, one of whom also reacted to isopropyl alcohol. Testing of 25 control persons gave negative results.
No takes yet. Share an insight, caveat, or question.
O. A. Jensen (1981) studied this question.