Key result
Recording F waves following 10 stimuli provides latency measurements within 1 ms of true values, while 20 stimuli provide mean latencies within 0.5 ms.
Why the study?
How many stimuli are required to obtain accurate normative F wave values in normal subjects?
Observational (n=11)
How many stimuli are required to obtain accurate normative F wave values in normal subjects?
Answers are grounded in this paper and cite their sources.
Recording 10 to 20 stimuli is sufficient for accurate mean latency measurements of F waves, though more stimuli are needed for chronodispersion and repeater waves.
No abstract yet. The journal hasn't published one we can show.
No takes yet. Share an insight, caveat, or question.
Fisher et al. (1994) conducted an observational in Healthy (n=11). Number of supramaximal stimuli vs. 100 stimuli ('true' values) was evaluated on F wave latency, persistence, chronodispersion, amplitude, and repeater waves. Recording F waves following 10 stimuli provides latency measurements within 1 ms of true values, while 20 stimuli provide mean latencies within 0.5 ms.