Key result
An immunochemical biosensor using a 3D polymer matrix achieved a limit of detection of 5 viral particles in 5 μl for tick-borne encephalitis virus, two orders of magnitude lower than conventional ELISA.
Why the study?
To improve the effectiveness of viral infection diagnostics by developing an immunochemical biosensor capable of detecting single viral particles using specific antibodies.
The novel 3D-matrix immunochemical biosensor provides highly sensitive detection of single viral particles, offering potential for rapid point-of-care viral diagnostics.
May enable single-particle viral detection; leaves open clinical validation before diagnostic adoption.
To improve the effectiveness of the viral infection diagnostic, we offer a new approach of immunochemical biosensors to determine single viral particles by specific antibodies. The antibodies are immobilized on the electrodes in a three‐dimensional polymer matrix with several layers of polyelectrolytes on the screen‐printed carbon electrode. Non‐covalent immobilization of antibodies in successive layers of positively charged polyethyleneimine (PEI) and negatively charged polystyrene sulfonate (PSS) achieves the effect of macromolecular crowding. Such an immobilization approach promotes the preservation of the optimal conformation and antibody active center mobility for interaction with large virion particles. We established an electrochemical biosensor for tick‐borne encephalitis virus (TBEV) detection to demonstrate the method's applicability. Under the optimized architecture of the 3D‐matrix, including a combination of two layers of a positively charged PEI with antibodies and the last layer of a negatively charged PSS, the assay is characterized by an extremely low limit of detection (LOD). This LOD could be as few as five viral particles in a sample volume of 5 μl, which is two orders of magnitude lower than conventional ELISA with the same reagents. The advantage of the biosensor is also a wide linear range of detection from 103 to 109 viral particles/ml. The proposed principle for determining virion particles is well suited to novel express diagnostics and Point‐of‐Care viral infections detection.
No takes yet. Share an insight, caveat, or question.
Baldina et al. (2022) studied Tick-borne encephalitis virus (TBEV) detection. Immunochemical biosensor with 3D polymer matrix (PEI and PSS) vs. Conventional ELISA was evaluated on Limit of detection (LOD) for viral particles. An immunochemical biosensor using a 3D polymer matrix achieved a limit of detection of 5 viral particles in 5 μl for tick-borne encephalitis virus, two orders of magnitude lower than conventional ELISA.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: