Validation of an analytical method for determining chloramphenicol residues in muscle tissue by gas chromatography-electron capture detection (GC-ECD) was performed according to the latest European Union criteria for the analysis of veterinary drugs in food, laid down by Commission Decision 2002/657/EC. The method using the meta isomer of chloramphenicol as an internal standard proved to be very selective, specific to other related phenicols and accurate to within +3.6% at a concentration level of 8.9 microg/kg, as present in the certified reference material available. The correlation coefficient of the calibration curve was 0.9991. At all three fortification levels studied (0.3, 0.45 and 0.6 microg/kg), repeatability and intra-laboratory reproducibility were <8 and < or =9%, respectively. The decision limit (CCalpha) and detection capability (CCbeta) were 0.07 and 0.12 microg/kg, respectively. The validation results and the results of participation in an international inter-laboratory proficiency test indicate that the method presented is completely suited for regulatory control to screen and quantify chloramphenicol residues in various muscle tissues on a routine basis.
No takes yet. Share an insight, caveat, or question.
Vesna Cerkvenik‐Flajs (2006) studied this question.
Synapse has enriched 5 related papers. Consider them for comparative context: