AIMS: To evaluate the inactivation of Bacillus anthracisΔSterne and Ames spores using electrochemically generated liquid-phase chlorine dioxide (eClO(2)) and compare two sporulation and decontamination methods with regard to cost, safety and technical constraints. METHODS AND RESULTS: Spores were prepared via agar and broth methods and subsequently inoculated and dried onto clean, autoclave-sterilized glass coupons. Bacillus anthracis spore inactivation efficacy was evaluated using the modified three-step method (AOAC 2008.05) and a single-tube extraction method. Spores (7·0 ± 0·5 logs) were inactivated within 1 min at room temperature using freshly prepared eClO(2). Bacillus anthracisΔSterne spores decreased in size after eClO(2) treatment as measured using a Beckman Coulter Multisizer. CONCLUSIONS: eClO(2) saturation of a hard surface was an effective B. anthracis sporicide. Broth sporulation and the single-tube extraction method required less time and fewer steps, yielded a higher percentage of phase-bright spores and showed higher spore recovery efficiency compared with AOAC 2008.05, making it more amenable to biosafety level 3 (BSL3) testing of virulent spores. SIGNIFICANCE AND IMPACT OF THE STUDY: Two test methods demonstrated the sporicidal efficacy of eClO(2). A new single-tube extraction test protocol for decontaminants was introduced.
No takes yet. Share an insight, caveat, or question.
Buhr et al. (2011) studied this question.
Synapse has enriched 5 related papers. Consider them for comparative context: