This is the authors' abstract. We don't add key points for this paper.
Micromixers have important applications in various pharmaceutical and medical fields. In the present study, the enhancement of mixing index in electroosmotic micromixer with different geometries is investigated. The commercial software COMSOL Multiphysics 5.4 is employed to solve the mathematical models. The SIMPLEC algorithm is employed for coupling the velocity and pressure fields. A second-order upwind scheme is used to reduce the artificial diffusivity. The results show a remarkable effect of the electric field on the mixing efficiency. The optimum geometry is the one with no obstacle in the mixing chamber. For the optimum geometry, it is demonstrated that the mixing efficiency increases with the voltage, however there are optimum values for frequency and inlet velocity in which the micromixer exhibits its best performance. The optimum values of frequency and inlet velocity are 8 Hz and 0.1 mm/s, respectively. It is revealed that the micromixer with no obstacle can reach the mixing efficiency of about 97%.
Answers are grounded in this paper and cite their sources.
No takes yet. Share an insight, caveat, or question.
Ghahfarokhi et al. (2021) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: