The authors report on an electrically variable Fabry-Pérot interferometer constructed from the organic material tris(8-hydroxyquinoline) aluminum (Alq3). A two-turn helical Alq3 film with a 300nm pitch is deposited via glancing angle deposition. Electrostatic compression of the nanosprings between parallel, partially reflective mirrors controls the peak transmission wavelength. Contact mode atomic force microscope measurements using a conductive tip indicate a spring compression of 1.2nm when a voltage of 6V is applied across the structure. Spectroscopic measurements show a 1.6nm shift in the peak transmission wavelength. These results demonstrate precise control of the transmission wavelength of an electrically variable nanometer scaled interferometer.
No takes yet. Share an insight, caveat, or question.
Dice et al. (2007) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: