Concrete beams retrofitted with bonded fiber reinforced plastic (FRP) plates often fail by debonding of the plate from the concrete surface. To predict the failure load in design, a proper debonding model is required. As debonding is a nonlinear process involving material softening, it can be analyzed once the interfacial shear (τ) versus sliding (s) relationship is known. Recent experimental results indicate that the simplest τ-s relationship should involve three parameters: the maximum shear stress for debonding to initiate, the initial residual stress right after debonding occurs, and a parameter governing the reduction of shear stress with sliding. In this paper, a FRP debonding model based on these three parameters is developed. The applicability of the model is verified through comparison with experimental results. Through a systematic parametric study, the effect of various material and geometric properties on the debonding process is investigated. Implications to the design of FRP strengthened members are highlighted.