Arrhenius plots are useful in predicting long-term use temperatures of organic materials and in choosing parameters for accelerated aging. For materials and components without established Arrhenius curves, a conservative value for the slope of the curve (which is also a measure of the activation energy of degradation) would allow longer-term predictions from a few short-term tests. Conversely, a required long-term temperature target can be extrapolated on the same slope to a range of short-time exposure temperatures suitable for accelerated tests. A review is made of available activation energies, from which values can be selected for conservative extrapolations on an Arrhenius plot.
No takes yet. Share an insight, caveat, or question.
R. M. W. Dixon (1980) studied this question.