A synchrotron transmission X-ray microscopy tomography system with a spatial resolution of 58.2 nm at the Advanced Photon Source was employed to obtain three-dimensional morphological data of all-solid Li-ion battery electrodes. The three-phase electrode was fabricated from a 47:47:6 (wt %) mixture of Li(Ni 1/3 Mn 1/3 Co 1/3 )O 2 as active material, Li 1.3 Ti 1.7 Al 0.3 (PO 4 ) 3 as Li-ion conductor, and Super-P carbon as electron conductor. The geometric analysis show that particle-based all-solid Li-ion battery has serious contact interface problem which significantly impact the Li-ion transport and intercalation reaction in the electrode, leading to low capacity, poor rate capability and cycle life.
No takes yet. Share an insight, caveat, or question.
Li et al. (2018) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: