In experiments on anode (ionization) double layers in nonuniform magnetic fields it has been noted that the magnetic field gradient seems to stabilize the double layer position. This effect is further investigated in a Q machine in which the magnetic field geometry could be varied. We find that the position of the double layers, along the axis of the device, could be controlled by changing the magnetic geometry. We account for this effect in a physical model which takes into account the effect of ion reflection by the magnetic mirror force in the region of magnetic field nonuniformity. This model is also able to account for variation of the double layer position when the neutral gas pressure is varied.