The integration of perovskite photodetectors with thin-film transistor (TFT) backplane or complementary metal-oxide-semiconductor CMOS circuit is a key step towards prototyping perovskite-based image sensors. Here, we demonstrate a pixel configuration for indirect X-ray detection comprising of IGZO TFTs and perovskite photodiodes (PDs). The perovskite photodiode is patterned by a two-step deposition method. Our integrated TFT/PD pixel shows a weak light detection capability down to 4 nW cm−2and a fast-transient response to the pulse light and gate switching. Combining with a CsI scintillator, the integrated pixel achieves a specific X-ray sensitivity of 8.28.2 × 10² μ C mGyₐᵢᵣ⁻¹ ~cm⁻³. Theoretically, with a state-of-the-art scintillator, the new pixel can provide a detectable signal for X-ray imaging at a dose rate as low as10 μ Gyₐᵢᵣ s⁻¹. This work provides an advanced pixel design for high resolution, high sensitivity, and high frame-rate flat-panel imager.