The influence of AC axial magnetic (AM) fields on the development of half-cycle drawn vacuum arcs is described. A Helmholtz coil provided an independent AC AM field B/sub ax//sup ac/ in the opening gap between flat profile, butt type, Cr-Cu contacts. For peak arc currents I/sub p/ up to 20 kA, critical AM fields B/sub crit//sup ac/ were determined, which prevented anode involvement. The dependence of B/sub crit//sup ac/ on I/sub p/ is compared with the analogous dependence using constant AM fields B/sub ax//sup DC/. These results extend the usefulness of the B/sub crit/ parameter to the design of contact structures for producing self-generated AM fields from the AC arcing current. A similar direct transition to the high-current diffuse arc mode can be maintained over the half-cycle without an imposed B/sub ax/ if I/sub p/>