This study investigates the robustness of a seismically designed steel moment frame building using 3-D nonlinear models. Computational simulations are carried out using validated models to investigate building response to loss of internal and external columns as well as columns in lower, middle and upper floors. Studies are conducted to gain insight into the sources of collapse resistance of the prototype building, focusing in particular on the role of composite action between the slab and underlying steel beams and slab membrane action. The simulation results suggest that the prototype building can be more vulnerable to loss of columns in the upper stories than in the lower ones and is particularly vulnerable to loss of interior gravity columns at all floor levels. The role of the slab is quantified and it is shown that it can contribute significantly to the robustness of the structure, but it is a double edge sword that can also be detrimental, especially in the final stages of collapse.