An evaluation of the efficacy of household air cleaning devices as a means to control radon decay products in existing buildings is presented. Previous research on air cleaning methods for airborne radon decay products has been directed primarily to the control of radon decay products in mines and has only limited application to control in residences where dust concentration, air change rate, and humidity are lower than in mines. Results show that room size air cleaners can achieve substantial reductions in working levels in residences. Reductions observed at air infiltration rates of 0.52 air changes per hour ranged from 58 to 89%. Although the two air cleaners tested produced the greatest reductions, the low cost, simplicity, and other benefits of air circulating fans, particularly the ceiling fan, appear to make them most suitable for residences. (JMT)