The effects of impurities in high temperature water has been examined on sensitized 304 stainless steel under both constant temperature and transient temperature conditions. As-welded, low temperature sensitized and furnace sensitized 304 has been studied under two conditions of potential control: by variable additions of oxygen and hydrogen peroxide in pure and impure water; and by potentiostat in a deaerated supporting electrolyte. Results have shown that impurity additions and transient temperature testing accelerate intergranular stress corrosion cracking, and that testing in supporting electrolytes often yields misleading results.
No takes yet. Share an insight, caveat, or question.
Andresen et al. (1982) studied this question.