Key result
Excessive ultrafiltration volume was the most dominant risk factor for intradialytic hypertension in hemodialysis patients, significantly increasing the odds of its occurrence (OR 29.52).
Why the study?
Intradialytic hypertension is a common complication in hemodialysis patients that must be controlled, prompting an evaluation of its contributing factors.
Do excessive interdialytic weight gain, poor fluid adherence, and excessive ultrafiltration increase the risk of intradialytic hypertension in hemodialysis patients?
Case-Control (n=92)
Yes
Do excessive interdialytic weight gain, poor fluid adherence, and excessive ultrafiltration increase the risk of intradialytic hypertension in hemodialysis patients?
Excessive ultrafiltration, excessive interdialytic weight gain, and poor fluid adherence are significant, modifiable risk factors for intradialytic hypertension in hemodialysis patients.
Answers are grounded in this paper and cite their sources.
May warrant fluid management attention in hemodialysis; hypothesis-generating for intradialytic hypertension risk pending prospective trials.
Intradialytic hypertension (IDH) is the most common complication of hemodialysis patients in Indonesia. It must be controlled, to maintain the patient's quality of life and prevent worsening conditions. Some factors affecting IDH include predialysis fluid overload characterized by excessive interdialytic weight gain (IDWG), low adherence to fluid restriction and increased ultrafiltration during haemodialysis. The study aims to identify contributing factors of IDH. A case-control design was used in this study. A purposive sampling technique was used to recruit 92 samples at two centres of dialysis in Semarang, which was divided into case group (n=46) and control group (n=46). Data were analyzed using the Chi-square test by calculating Odds Ratios (OR). The finding showed that excessive IDWG (p=0,000, OR=16.95, 95% CI:5,56-51,65), low fluid adherence (p=0,001, OR=4,41, 95% CI:1,82-10,68) and excessive ultrafiltration (p=0,000, OR = 29,52, 95% CI:9,23-94,46) showed significant result. However, the incidence of IDH was not correlated with sex, age and length of haemodialysis. A greater increase in interdialytic weight requires lower fluid and higher ultrafiltration factors must be controlled precisely because those are considered as the risk factors for the high incidence of IDH. Excessive ultrafiltration is the most dominant risk factor in the high incidence of IDH.
No takes yet. Share an insight, caveat, or question.
Armiyati et al. (2021) conducted a case-control in Intradialytic hypertension in hemodialysis patients (n=92). Excessive ultrafiltration volume vs. Normal ultrafiltration volume was evaluated on Incidence of intradialytic hypertension (IDH) (OR 29.52, 95% CI 9.23-94.46, p=<0.001). Excessive ultrafiltration volume was the most dominant risk factor for intradialytic hypertension in hemodialysis patients, significantly increasing the odds of its occurrence (OR 29.52).
Synapse has enriched 10 related papers. Consider them for comparative context: