An air-assisted electrostatic nozzle uses a combination of air-assisted atomization and electrostatic spray technology. This article optimizes the existing air-assisted electrostatic nozzles in terms of structural design to obtain a higher charge-to-mass ratio and a smaller droplet size. The optimized air-assisted electrostatic nozzle was studied experimentally, and the effects of liquid pressure, air pressure and applied voltage on the droplet size and charge-to-mass ratio were investigated. Comparing the effects of air pressure, liquid pressure and applied voltage on the charge-to-mass ratio and droplet size, the relationship curves of the droplet size and charge-to-mass ratio under each voltage were fitted using the Rayleigh charge limit theory. For a higher CMR during the spray operation, applied voltages between 2.5 kV and 3 kV, an air pressure between 0.4 bar and 0.6 bar, and a liquid pressure of less than 0.9 bar could be chosen. The optimized air-assisted electrostatic nozzles not only have small droplets but also have high charge-to-mass ratios, reducing the need for pesticide use and thus protecting human health and the environment.
No takes yet. Share an insight, caveat, or question.
Dai et al. (2022) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: