Superconducting integrated circuits should be operated at low temperature below a half of their critical temperatures. Thermal heat from a bias resistor could rise the temperature in Josephson junctions, and would reduce their critical currents. In this study, we estimate the temperature in a Josephson junction heated by a bias resistor at the bath temperature of 4.2K, and introduce a parameter β that connects the thermal heat from a bias resistor and the temperature elevation of a Josephson junction. By using β, the temperature in the Josephson junction can be estimated as functions of the current through the resistor.
No takes yet. Share an insight, caveat, or question.
Keisuke et al. (2012) studied this question.