Key result
Transseptal puncture without fluoroscopy using a radiofrequency needle, a 3D navigation system, and transesophageal echocardiography was successfully performed in 10 patients without any complications.
Why the study?
Non-fluoroscopy approaches using 3D navigation systems are increasingly recognized for treating arrhythmias, but limited data exist regarding transseptal puncture performed without fluoroscopy.
Does transseptal puncture without fluoroscopy using a radiofrequency needle prevent complications in patients undergoing arrhythmia ablation?
Observational (n=10)
No
Does transseptal puncture without fluoroscopy using a radiofrequency needle prevent complications in patients undergoing arrhythmia ablation?
Transseptal puncture without fluoroscopy using a radiofrequency needle, 3D navigation, and transesophageal echocardiography appears safe and effective in a small case series.
Answers are grounded in this paper and cite their sources.
Feasibility of fluoroless transseptal puncture shown in small series; leaves open larger prospective trials before adoption.
BACKGROUND: The non-fluoroscopy approach with the use of a three-dimensional (3D) navigation system is increasingly recognized as a future technology in the treatment of arrhythmias. However, there are a limited number of articles published concerning transseptal puncture without the use of fluoroscopy. METHODS: Presented in this paper is the first series of patients (n = 10) that have undergone transseptal puncture without the use of fluoroscopy under transesophageal echocardiography control using a radiofrequency transseptal needle and a 3D navigation system. RESULTS: All patients were treated without complications. In 6 patients, re-pulmonary vein isolation was performed. In 5 cases, linear ablation of the left atrium for treatment of left atrial macro re-entry tachycardia was provided. In 2 patients, focal atrial tachycardia was treated, 1 patient underwent cavo tricuspidal isthmus (CTI) ablation and 1 patient, re-CTI ablation. The ablation of complex fragmented atrial electrograms was done in 2 patients. In 1 case, right atrial macro re-entry tachycardia was treated. CONCLUSIONS: Transseptal puncture without using fluoroscopy is safe and effective when using a radiofrequency needle, a 3D navigation system and transesophageal echocardiography.
No takes yet. Share an insight, caveat, or question.
Imnadze et al. (2020) conducted an observational in Atrial fibrillation and other arrhythmias requiring transseptal puncture (n=10). Transseptal puncture without fluoroscopy using a radiofrequency needle was evaluated on Procedural success and complications. Transseptal puncture without fluoroscopy using a radiofrequency needle, a 3D navigation system, and transesophageal echocardiography was successfully performed in 10 patients without any complications.
Synapse has enriched 10 related papers. Consider them for comparative context: