Key result
Myotubes from patients with Andersen's syndrome exhibited an absence of inwardly rectifying Ba2+-sensitive current and a depolarized resting membrane potential compared to controls.
Case-Control
Ex vivo analysis of human myotubes from Andersen's syndrome patients demonstrates a loss of Ik1 current and depolarized resting membrane potential, providing functional clues to the skeletal muscle pathophysiology.
Answers are grounded in this paper and cite their sources.
Ex vivo IK1 loss in Andersen myotubes supports mechanistic studies; leaves open clinical translation or targeted therapies.
Andersen's syndrome is a rare disorder that has been defined with a triad: periodic paralysis, cardiac arrhythmia, and development anomalies. Muscle weakness has been reported in two-thirds of the patients. KCNJ2 remains the only gene linked to Andersen's syndrome; this gene encodes for the alpha-subunit of the strong inward-rectifier K+ channel Kir2.1. Several studies have shown that Andersen's syndrome mutations lead to a loss of function of the K+ channel activity in vitro. However, ex vivo studies on isolated patient muscle tissue have not been reported. We have performed muscle biopsies of controls and patients presenting with clinically and genetically defined Andersen's syndrome disorder. Myoblasts were cultured and characterized morphologically and functionally using the whole cell patch-clamp technique. No morphological difference was observed between Andersen's syndrome and control myoblasts at each passage of the cell culture. Cellular proliferation and viability were quantified in parallel with direct cell counts and showed no difference between control and Andersen's syndrome patients. Moreover, our data show no significant difference in myoblast fusion index among Andersen's syndrome and control patients. Current recordings carried out on myotubes revealed the absence of an inwardly rectifying Ba2+-sensitive current in affected patient cells. One consequence of the Ik1 current loss in Andersen's syndrome myotubes is a shift of the resting membrane potential toward depolarizing potentials. Our data describe for the first time the functional consequences of Andersen's syndrome mutations ex vivo and provide clues to the K+ channel pathophysiology in skeletal muscle.
No takes yet. Share an insight, caveat, or question.
Sacconi et al. (2009) conducted a case-control in Andersen's syndrome. Andersen's syndrome mutations vs. Controls was evaluated on Morphological and functional characteristics of cultured myoblasts and myotubes (Ik1 current, resting membrane potential). Myotubes from patients with Andersen's syndrome exhibited an absence of inwardly rectifying Ba2+-sensitive current and a depolarized resting membrane potential compared to controls.