Key result
Standard functional measures in adult SMA demonstrate excellent short-term test-retest reliability with ICCs >0.95.
Why the study?
Disease-modifying therapies for SMA require standardized follow-up, but short-term changes may reflect measurement variability rather than true clinical change.
Observational (n=44)
No
Effect estimate: ICC >0.95
Commonly used functional measures in adults with SMA show high short-term reliability, establishing that variations up to 10% likely reflect measurement variability rather than true clinical change.
High short-term reliability supports distinguishing error from change in adult SMA; extends validation but leaves open responsiveness assessment.
Background Disease-modifying therapies for spinal muscular atrophy (SMA) require standardized follow-up to interpret treatment response. However, short-term changes may reflect measurement variability rather than true clinical change. We therefore assessed the test-retest reliability and relationships of routinely used outcome measures in adults with SMA using two standardized evaluations performed within a two-week interval. These assessments included motor function, upper-limb strength and dexterity, ambulatory performance, and respiratory function. Results Forty-four adults with SMA type 2 or 3 were included. No significant change was observed between test and retest visits. Most outcomes demonstrated excellent reproducibility, with intraclass correlation coefficients (ICC) >0.95. Measurement errors were low, with relative standard errors of measurement below 10% for most outcomes. Strong correlations were observed among most outcomes ( p < 0.001). Conclusions Commonly used functional measures in adults with SMA show high short-term reliability. Based on reliability, measurement error, and inter-test correlations, grip strength, MFM, RULM, and FVC appear to be among the most reliable measures, although RULM may be limited by known ceiling and floor effects.
No takes yet. Share an insight, caveat, or question.
García-Alcántara et al. (2026) conducted an observational in Spinal muscular atrophy (SMA) type 2 or 3 (n=44). Standardized functional assessments vs. Retest assessment was evaluated on Test-retest reliability (Intraclass correlation coefficients) (ICC >0.95). Commonly used functional outcome measures in adults with spinal muscular atrophy, including grip strength, MFM, RULM, and FVC, demonstrated excellent short-term test-retest reliability with intraclass correlation coefficients >0.95.