Answers are grounded in this paper and cite their sources.
Biofilms causing biomaterial-associated infection resist antibiotic treatment and usually necessitate the replacement of infected implants. Here we relate bacterial adhesion forces and the antibiotic susceptibility of biofilms on uncoated and polymer brush-coated silicone rubber. Nine strains of Staphylococcus aureus, Staphylococcus epidermidis, and Pseudomonas aeruginosa adhered more weakly to brush-coated silicone rubber (-0.05 ± 0.03 to -0.51 ± 0.62 nN) than to uncoated silicone rubber (-1.05 ± 0.46 to -5.1 ± 1.3 nN). Biofilms of weakly adhering organisms on polymer brush coatings remained in a planktonic state, susceptible to gentamicin, unlike biofilms formed on uncoated silicone rubber.
No takes yet. Share an insight, caveat, or question.
Muszanska et al. (2012) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: