In this paper, a high-performance unity-power-factor rectifier-inverter structure is presented. A synchronous-reference-frame-based hysteresis current control as inner loop and dc-link voltage control as outer loop are adopted for the front-end converter. With the proposed control algorithm, the converter draws high-quality sinusoidal supply currents and maintains good dc-link-voltage regulation under wide load variation, and even under unbalanced and nonsinusoidal supply voltage conditions. Theoretical results of its analysis are verified initially through digital simulation. Finally, experimental results of a 1-kVA laboratory prototype system confirm the feasibility of the proposed technique
No takes yet. Share an insight, caveat, or question.
Maswood et al. (2007) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: