Background: investigation was to investigate how composite translucency affected the accuracy of IOS. Material and Methods: GC G-aenial Universal Injectable JE composite plates were used for the study at 3 thicknesses (1-2-3mm). A lab scanner (3Shape E1) obtained 1 reference scan, whereas IOS (Trios3) was used to conduct 10 experimental scans per group. After 3D superimposition, deviation values were used to assess the accuracy (trueness and precision) outcomes for the corresponding groups. Using an LS170 V2.0 colorimeter, the translucency parameter (TP) of the plates was determined from L*a*b* values of CIELAB color space. Results: The composite translucency resulted in a decrease in the scale of digital impressions. The 1mm group had the largest scale reduction (0.02mm) significantly, followed by the 2mm and 3mm groups (0.01mm). No difference was found in mean precision. The colorimeter detects the L*a*b* values and showed that 1mm composite plate expressed the highest TP value, then 2mm and 3mm groups (28.90, 14.26 and 6.49 respectively). The thinner composite, the higher translucency and TP were highly positively correlated to IOS trueness of composite plates. Conclusions: Accuracy, translucency, resin composite, digital dentistry, intraoral-scanner.
No takes yet. Share an insight, caveat, or question.
Huynh et al. (2024) studied this question.
Synapse has enriched 5 related papers. Consider them for comparative context: