This is the authors' abstract. We don't add key points for this paper.
Flat-panel X-ray detectors are indispensable in a variety of imaging applications ranging from medical radiography to industrial inspections. Current commercial detectors (α-Se/CdTe) suffer from unsatisfactory image contrast and high-dose X-ray exposure owing to the limited attenuation and charge collection. Here, we show that heterovalent-doped Sb 2 S 3 glass (α-Sb 2 S 3 ) can effectively convert X-ray photons to electrical current signals. SnI 2 doping modifies the Sb–S network and stabilizes the noncrystalline structure, enabling bulk α-Sb 2 S 3 with a narrow bandgap (1.66 eV), large mobility-lifetime product (5.6 × 10 –5 cm 2 V –1 ), and strong radiation attenuation capacity simultaneously. The α-Sb 2 S 3 -based detector exhibits a high sensitivity of 4397 μC Gy 1– cm –2, a low detection limit of 66 nGy s –1, and excellent stability. Thermally evaporated α-Sb 2 S 3 on a pixelated thin film transistor (TFT) backplane enables high-resolution X-ray imaging. This is the first demonstration of Sb 2 S 3 -based X-ray detection and imaging, creating new possibilities for the development of amorphous semiconducting materials and devices.
Answers are grounded in this paper and cite their sources.
No takes yet. Share an insight, caveat, or question.
Li et al. (2025) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: