Key result
Transseptal puncture during transcatheter edge-to-edge mitral valve repair demonstrated a substantial learning curve, peaking at 49 cases to achieve acceptable efficiency.
Why the study?
Effective transseptal puncture is mandatory for TEER but can be time-consuming and carry complications, and the learning curve for a dedicated structural heart team needed examination.
What is the learning curve for transseptal puncture during transcatheter edge-to-edge mitral valve repair?
Observational (n=107)
What is the learning curve for transseptal puncture during transcatheter edge-to-edge mitral valve repair?
Transseptal puncture during TEER has a substantial learning curve, requiring approximately 50 cases to achieve acceptable efficiency.
OBJECTIVE: This study examined the learning curve for transseptal puncture (TSP) during transcatheter edge-to-edge mitral valve repair (TEER) performed by a dedicated mitral valve structural heart team. Effective TSP is mandatory for TEER but can be time-consuming and associated with complications including pericardial effusion and cardiac tamponade. METHODS: TSP was performed on 107 consecutive patients (76 ± 1 years, 52% male) undergoing TEER between 2014 and 2019. TSP was performed by each structural heart team member (1 cardiologist, 2 cardiac surgeons) on a rotating case-by-case basis. No team member had prior independent TSP experience. Data collected included total procedure time, TSP time (time elapsed between procedure start and septal crossing), and number of TSP attempts before successful puncture. Cumulative sum (CUSUM) of deviations from the mean across sequential cases were used to examine learning curves. The majority of patients required only 1 TSP attempt (79%). There was a significant quadratic relationship between case number and the CUSUM for TSP time, with the learning curve peaking at 49 cases. CONCLUSIONS: TSP for TEER has a substantial learning curve, requiring >50 cases to achieve acceptable efficiency. Even once proficiency is demonstrated, TSP remains a time-consuming component of TEER. Improvements in transseptal access technology may significantly decrease the time needed to master TSP and may improve the safety and precision of the procedure.
No takes yet. Share an insight, caveat, or question.
Quinn et al. (2021) conducted an observational in Transcatheter edge-to-edge mitral valve repair (TEER) (n=107). Transseptal puncture (TSP) was evaluated on Learning curve for TSP time (CUSUM of deviations from the mean). Transseptal puncture during transcatheter edge-to-edge mitral valve repair demonstrated a substantial learning curve, peaking at 49 cases to achieve acceptable efficiency.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: