This paper presents the new fundamental step-up method for standard voltage transformers (VTs) at the Physikalisch-Technische Bundesanstalt, as well as the setup of the required components. A main component is an active lowvoltage capacitor, designed to realize capacitive voltage dividers by means of compressed gas, high-voltage capacitors for rated primary voltages between 5 kV and 800 kV/V3. This divider has a negligible voltage dependence and low phase errors at 50/60 Hz. Using the other components, mainly a two-stage VT with integrated inductive voltage divider and a sampling-based voltage comparator, a transfer uncertainty for one build-up step of below 1 · 10-6(k = 2) has been reached.
No takes yet. Share an insight, caveat, or question.
Mohns et al. (2018) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: