As a consequence of recent improvements to the far-infrared (FIR) interferometer time response, from bandwidth of 10 kHz up to 1 MHz, high-frequency density fluctuations can now be resolved on the Madison symmetric torus (MST) reversed-field pinch. The phase measurement allows absolute calibration of the fluctuation amplitude while eleven chords generate information on the spatial distribution. Density fluctuations up to 200 kHz are observed. A unique feature of the MST interferometer is that six chords are toroidally displaced 5° from the remaining five. Hence, besides information on the poloidal structure, i.e., m=1, toroidal information is also available. By computing the cross power, coherence, and cross phase between two toroidally displaced chords, one can determine the toroidal rotation speed, dispersion, and correlation length.
No takes yet. Share an insight, caveat, or question.
Jiang et al. (1999) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: