The HCN-interferometer/polarimeter on TEXTOR has been extended by a horizontal line of sight in the equatorial plane. The achieved signal to noise ratio and the time resolution of this polarimeter channel are sufficient to resolve the m = 1 magnetic precursor oscillation before the sawtooth collapse. The growth rate of the precursor oscillation in a sawtoothing ohmically heated discharge has been determined to be . The magnetic perturbation, determined from the Faraday rotation integral, assuming a kink-mode eigenfunction, is 13 mT just before the sawtooth crash and the `displacement' of the core is about 0.9 cm or . The amplitude of a stationary m = 1 mode observed in an additionally heated discharge with balanced neutral beam injection amounts to 26 mT.
No takes yet. Share an insight, caveat, or question.
Koslowski et al. (1996) studied this question.
Synapse has enriched 4 closely related papers on similar clinical questions. Consider them for comparative context: