This is the authors' abstract. We don't add key points for this paper.
We examine the projection approximation in the context of propagation-based phase contrast imaging using hard x-rays. Specifically, we consider the case of a cylinder or a rounded edge, as a simple model for the edges of many biological samples. The Argand-plane signature of a propagation-based phase contrast fringe from the edge of a cylinder is studied, and the evolution of this signature with propagation. This, along with experimental images obtained using a synchrotron source, reveals how propagation within the scattering volume is not fully described in the projection approximation's ray-based approach. This means that phase contrast fringes are underestimated by the projection approximation at a short object-to-detector propagation distance, namely a distance comparable to the free-space propagation within the volume. This failure of the projection approximation may become non-negligible in the detailed study of small anatomical features deep within a large body. Nevertheless, the projection approximation matches the exact solution for a larger propagation distance typical of those used in biomedical phase contrast imaging.
Answers are grounded in this paper and cite their sources.
No takes yet. Share an insight, caveat, or question.
Morgan et al. (2010) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: