Answers are grounded in this paper and cite their sources.
The objective of this effort is to provide guidance for the determination of spectral resolution for the passive remote detection of organic vapors. Target bands were modeled as Lorentzian bands. Several sensor models were used, including a detector-limited sensor model and a background-limited model. An expression for the signal-to-noise ratio (SNR) was derived, and the SNR was computed for an SF(6) target band. The results show that substantial gains in sensitivity are possible if the conventional laboratory spectral resolution of 2 cm(-1) is reduced to 8 or even 16 cm(-1).
No takes yet. Share an insight, caveat, or question.
Dennis F. Flanigan (1995) studied this question.
Synapse has enriched 5 related papers. Consider them for comparative context: