Cathode spot formation in laser-induced breakdown in vacuum was investigated by laser absorption photography with high spatial (0.5 /spl mu/m) and temporal (100 ps) resolution. The discharge was initiated between Cu electrodes with a cathode-anode distance of 15-250 /spl mu/m. The duration of pulsed discharges was 750 ns and dc discharges some milliseconds; the current was below 10 A. Picosecond momentary absorption photography yielded spatial-temporal density distributions in the ignition phase of the cathode spot. An absolute electron density >5/spl times/10/sup 26/ m/sup -3/ in narrow plasma fragments with a diameter smaller than 5 /spl mu/m was estimated. Mathematical modeling has satisfactorily explained the formation of the narrow plasma channel due to the bulk current self-focusing, as well as due to the generation of nonstationary emissive centers at the moving boundary of the expanding cathode spot plasma.