Practical experience has shown that thermal shock tests do not lead to generally useful test data. This is probably due to the fact that thermal shock failure is a complicated function of the external thermal shock conditions and of the temperature functions of five different material properties. These five material functions appear in a different combination in almost every thermal shock case and cannot be extracted from thermal shock test data. It is recommended that these five properties and their temperature dependence be determined by separate standard tests, not employing thermal shock. If the five property functions are known, thermal shock tests proper can be used to determine the maximum thermal shock stresses in any device.
No takes yet. Share an insight, caveat, or question.
W. R. Buessem (1955) studied this question.