The goal of this study is to provide pump users a simple means to predict a pump's performance change due to changing fluid viscosity. During the initial investigation, it has been demonstrated that pump performance can be represented in terms of the head coefficient, flow coefficient, and rotational Reynolds number with the head coefficient data for all viscosities falling on the same curve when presented as a function of ф*Rew−a. Further evaluation of the pump using computational fluid dynamics (CFD) simulations for wider range of viscosities demonstrated that the value of a (Morrison number) changes as the rotational Reynolds number increases. There is a sharp change in Morrison number in the range of 104
No takes yet. Share an insight, caveat, or question.
Patil et al. (2018) studied this question.