Quality controls of serological assays have to contain defined amounts of human antibodies specific for the targeted antigen. A prevailing issue for array-based antigen assays is that dozens of antigens are targeted within the same assay. Commonly different patient sera are combined and optimal pools are empirically identified. Here, we report a mathematical approach how an optimal sample pool composition can be systematically calculated and accurately compiled. The approach was used to compose suitable quality controls for a 71 plex Tuberculosis antigen bead array using a limited number of positive human sera.
No takes yet. Share an insight, caveat, or question.
Planatscher et al. (2013) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: